5780 EMI Flexible absorber sheets

The EMI flexible absorber sheets developed for electromagnetic wave absorber and noise suppression can eliminate noise effectively

The EMI flexible absorber sheets developed for electromagnetic wave absorber and noise suppression can eliminate noise effectively. You can solve EMC/EMI problems by attaching noise suppression sheets simply on the parts of noise sources.


Features and benefits

  • Very flexible and easy to handle
  • Can be deliverd in any shape, size and/or thickness
  • Optionally available as custom made tube
  • Can be cut according to your supplied drawings
  • Provide effective EMI suppression in a wide frequency range (10MHz to 18GHz)
  • Change the magnetic flux path to avoid interference on other components or surrounding cables
  • Reduce the eddy current when the magnetic flux is close to metal
  • Non-conductive adhesive backing (UL Recognized)
    available
  • Effective in preventing resonance and suppressing coupling
  • High surface resistance (>106 ohms)
  • Easy and fast to process through self adhesive
Several types of flexible EMI absorber sheets
Several types of flexible EMI absorber sheets
Flexible EMI absorber sheet is easy to bend around a cable (optional available as an tube)
Flexible EMI absorber sheet is easy to bend around a cable (optional available as an tube)

Applications

  • RFID (Radio Frequency Identification) systems
  • NFC (Near field communication)
  • Wireless Power Chargers (WPC / Qi)
  • Computers (NB / Desktop / Tablet) and peripherals • Digital Products
  • Mobile Phones / Smart Phones / Phablet
  • Wireless equipments
  • EMI Shielding Box / Dark Box
  • Between printed circuit boards
  • On ICs, processors, and controllers
  • On cables that need high flexibility

Part number and characteristics

Properties Unit 5780-C1 5780-C3 5780-C5 5780-C7 5780-C8
Operating Temperature -40 ~ +85 -40 ~ +85 -40 ~ +85 -40 ~ +85 -40 ~ +85
Applicable Frequency GHz 0.01 – 8.0 0.1 – 18.0 0.01 – 18.0 0.01 – 1.0 0.01 – 1.0
Relative permeability (μ’@1MHz) - 25 50 115 140 450
Material - Magnetic Powder
+ Rubber
Magnetic Powder
+ Rubber
Magnetic Powder
+ Rubber
Sintered Ferrite Sintered Ferrite
Thickness Range mm 0.12 - 2.50 0.25 / 0.50 / 0.75 0.05 - 0.50 0.08 / 0.12 0.12 / 0.22
Max. Dimension mm 400 x 400 400 x 400 210 x 297 (A4) 130 x 130 130 x 130
Surface Resistance Ohm 106 109 106 109 109
Density g/cm3 3.6 4.8 2.7 3.8 3.8
RoHS 2.0 Compliance - 2011/65/EU 2011/65/EU 2011/65/EU 2011/65/EU 2011/65/EU
Halogen-Free - No No Yes Yes Yes

Usage examples

Example 1: Wrap around a cable
Example 1: Wrap around a cable
Example 2: Apply to flat cable
Example 2: Apply to flat cable
Example 3: Aplpy to a integrated circuit (IC) top
Example 3: Aplpy to a integrated circuit (IC) top
Example 4: Apply between integrated circuit
Example 4: Apply between integrated circuit
Example 5: Apply to case and between boards
Example 5: Apply to case and between boards

EMI enclosure solutions using only EMI shielding tapes or with EMI absorbers

EMI enclosure solutions using only EMI shielding tapes
EMI enclosure solutions using only EMI shielding tapes
EMI enclosure solutions using EMI shielding tapes and EMI absorbers
EMI enclosure solutions using EMI shielding tapes and EMI absorbers

Effect diagram - Magnetic shield

5780-Effect-Diagram-magnetic-shield

5780 EMI Flexible absorber sheets can change the magnetic flux path to avoid the magnetic flux affect others components.

Effect diagram - RFID/NFC on metal

5780-Effect-Diagram-RFID-NFC-on-metal

The magnetic flux induced eddy current and generated a reverse magnetic field to offset the
magnetic flux to cancel the communication. After attached 5780 between metal and RFID
antenna, the communication will recover.

Effect diagram - Wireless Power Charger

5780 EMI Flexible absorber sheets can be used for wireless power charger to avoid eddy current when RX coil attached on
metal and change the magnetic flux path between TX coil, RX coil, magnet.

Permeability characteristics

5780-C1, 5780-C3, 5780-C6 EMI Flexible absorber sheets permeability characteristics
5780-C1, 5780-C3, 5780-C6 EMI Flexible absorber sheets permeability characteristics
5780-C5, 5780-C7, 5780-C8 EMI Flexible absorber sheets permeability characteristics
5780-C5, 5780-C7, 5780-C8 EMI Flexible absorber sheets permeability characteristics

Methods of measurement

5780 EMI Flexible absorber sheets power loss measurement
5780 EMI Flexible absorber sheets power loss measurement
5780 EMI Flexible absorber sheets reflection loss measurement
5780 EMI Flexible absorber sheets reflection loss measurement

Return loss at a given frequency

5780 EMI Flexible absorber sheets return loss at a given frequency
5780 EMI Flexible absorber sheets return loss at a given frequency

Pick the right EMI flexible absorber sheet

Item 5780-C1 5780-C3 5780-C5 5780-C7 5780-C8
Economic Best Good Poor Middle Middle
Operation temperature -40 ~ +85 C° -30 ~ +120 C°
Material Magnetic Powder + Rubber Sintered Ferrite
Relative permeability (μ’@1MHz) 25 50 115 140 450
Thinnest version 0.12 mm 0.25 mm 0.05 mm 0.08 mm 0.12 mm
Thickest version 2.50 mm 0.75 mm 0.50 mm 0.12 mm 0.22 mm
Surface Resistance 106 109 106 109 109
RoHS 2.0 Compliance 2011/65/EU
Halogen-Free No Yes
Best Application RFID/NFC EMI, RFID/NFC EMI, RFID/NFC Wireless Charger (no magnet type) EMI, RFID/NFC Wireless Charger (no magnet type)

 

To get a quotation for EMI Absorber sheets within 24 hours fill in the form below.

Series
Type
Select an option:
C1 : Magnetic powder + rubber
C3 : Magnetic powder + rubber
C5 : Magnetic powder + rubber
C6 : Magnetic powder + rubber
C7 : Sintered ferrite
C8 : Sintered ferrite
Width (mm)
Specify the width in mm
Length (mm)
Specify the length in mm
Thickness (mm)
Specify the desired thickness. The options can be found in the table above.
* Note: The red blocks are required

TC